4820-01-353-2858 VALVE,BALL Index 5307-01-353-2860 STUD,PLAIN

National Stock Number:
5915-01-353-2859

Federal Supply Class:
5915

National Item Identification Number:
013532859

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
124A307-103640LOCKHEED MARTIN CORPORATION
52-577-00133095SPECTRUM CONTROL INC


Techincal Specification:
AVERAGE LIFE RATING IN HOURS200000.0
BODY MATERIALALUMINUM
BODY SURFACE TREATMENTTIN
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.290 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.600 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD INPUT 1ST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
NUCLEAR HARDNESS CRITICAL FEATUREHARDENED
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.5 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.5 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.5 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
MAXIMUM TEMP RISE45.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
SPECIAL FEATURESNUCLEAR HARDNESS CRITICAL ITEMS
UNPACKAGED UNIT WEIGHT1.500 POUNDS NOMINAL
UNTHREADED MOUNTING HOLE DIAMETER0.235 INCHES NOMINAL
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0


Click here to Register for Free 30-day Trial