AVERAGE LIFE RATING IN HOURS | 10000.0 |
BODY HEIGHT | 2.340 INCHES NOMINAL |
BODY LENGTH | 4.720 INCHES NOMINAL |
BODY MATERIAL | METAL |
BODY WIDTH | 2.590 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.000 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.000 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD GROUND 3RD FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 THREADED STUD OUTPUT 2ND FUNCTION |
FEATURES PROVIDED | SHOCK RESISTANT |
INCLOSURE TYPE | ENCASED |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING TEMP RANGE | -54.0 TO 85.0 CELSIUS |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
OVERALL HEIGHT | 3.077 INCHES NOMINAL |
OVERALL LENGTH | 5.020 INCHES NOMINAL |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.0 KILOVOLTS AT SEA LEVEL |
MAXIMUM TEMP RISE | 30.0 CELSIUS |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.138 INCHES |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
UNPACKAGED UNIT WEIGHT | 3.300 POUNDS NOMINAL |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES |