BODY LENGTH | 3.312 INCHES NOMINAL |
BODY MATERIAL | METAL |
BODY WIDTH | 3.750 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.750 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.000 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD GROUND 3RD FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 THREADED STUD OUTPUT 2ND FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 THREADED STUD INPUT 1ST FUNCTION |
FEATURES PROVIDED | NUT AND WASHER |
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.15 AND 0.5 AND 1.0 AND 5.0 AND 10.0 AND 30.0 |
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 15.0 AND 30.0 AND 33.0 AND 65.0 AND 55.0 |
INCLOSURE TYPE | ENCASED |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 20.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 20.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING TEMP RANGE | -55.0 TO 125.0 CELSIUS |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
OVERALL HEIGHT | 1.520 INCHES NOMINAL |
OVERALL LENGTH | 4.140 INCHES NOMINAL |
OVERALL WIDTH | 5.075 INCHES NOMINAL |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.45 KILOVOLTS AT SEA LEVEL |
MAXIMUM TEMP RISE | 40.0 CELSIUS |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
MOUNTING SLOT WIDTH | 0.156 INCHES NOMINAL |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
SPECIAL FEATURES | TWO FILTERED FUNCTIONS |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |