AVERAGE LIFE RATING IN HOURS | 250.0 |
BODY HEIGHT | 9.500 INCHES NOMINAL |
BODY LENGTH | 5.500 INCHES NOMINAL |
BODY WIDTH | 2.250 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.620 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.500 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD INPUT 1ST FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD OUTPUT 2ND FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 THREADED STUD GROUND 3RD FUNCTION |
INCLOSURE TYPE | ENCASED |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
OVERALL HEIGHT | 11.000 INCHES NOMINAL |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 2250.0 VOLTS AT SEA LEVEL |
MAXIMUM TEMP RISE | 25.0 CELSIUS |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED STUD 1ST FUNCTION |
NOMINAL THREAD SIZE | 0.164 INCHES |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.5 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.5 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.5 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.5 4TH RADIO INTERFERENCE 4TH FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
SPECIAL FEATURES | ONE UNFILTERED FUNCTION |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 55.0 |