5935-01-167-3366 CONNECTOR BODY,RECEPTACLE,ELECTR Index 5935-01-167-3368 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5915-01-167-3367

Federal Supply Class:
5915

National Item Identification Number:
011673367

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
0098-LL-TJ2-245653711NAVAL SEA SYSTEMS COMMAND
452-40020-41PY(100)03554AMPHENOL CANADA CORP
5189010-00853711NAVAL SEA SYSTEMS COMMAND
5915PL09866809009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
81019-20-41PY11139TE CONNECTIVITY CORPORATION


Techincal Specification:
BODY MATERIALALUMINUM
BODY SURFACE TREATMENTCADMIUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY41 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT
FEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONMIL-C-26482
INPUT TERMINAL MANUFACTURER CODE11139
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 1ST RADIO INTERFERENCE AND 800.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 2ND RADIO INTERFERENCE AND 800.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 3RD RADIO INTERFERENCE AND 800.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 4TH RADIO INTERFERENCE AND 800.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 5TH RADIO INTERFERENCE AND 800.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 6TH RADIO INTERFERENCE AND 800.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
OUTPUT TERMINAL IDENTIFICATIONMIL-C-26482
OUTPUT TERMINAL MANUFACTURER CODE11139
OVERALL HEIGHT1.796 INCHES MINIMUM AND 1.828 INCHES MAXIMUM
OVERALL LENGTH2.264 INCHES NOMINAL
OVERALL WIDTH1.796 INCHES MINIMUM AND 1.828 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE1.5 KILOVOLTS AT SEA LEVEL
MAXIMUM TEMP RISE25.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 1ST RADIO INTERFERENCE AND 8.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 2ND RADIO INTERFERENCE AND 8.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 6TH RADIO INTERFERENCE AND 8.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 3RD RADIO INTERFERENCE AND 8.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 4TH RADIO INTERFERENCE AND 8.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 5TH RADIO INTERFERENCE AND 8.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNEF
NOMINAL THREAD SIZE1.375 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE 4TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 5TH RADIO INTERFERENCE 5TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 6TH RADIO INTERFERENCE 6TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
PRECIOUS MATERIAL AND LOCATIONCONTACT SURFACES SILVER
PRECIOUS MATERIALSILVER
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
SPECIAL FEATURESFORTY-ONE FILTERED FUNCTIONS
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
STYLE DESIGNATORFILTER CONNECTOR