5915-01-076-4533 FILTER,BAND PASS Index 5915-01-076-4536 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-076-4534

Federal Supply Class:
5915

National Item Identification Number:
010764534

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
FC462960583STELLANT SYSTEMS, INC
SM-A-9448441VPW8GENERAL DYNAMICS MISSION SYSTEMS, INC.
SM-A-94484460583STELLANT SYSTEMS, INC
SM-A-94484494990MOTOROLA INC. DBA INTEGRATED INFORMATION SYSTEMS GROUP


Techincal Specification:
BODY LENGTH2.700 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS55.0 MINIMUM BLANK AND 1.00 MAXIMUM BLANK 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.690 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.605 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION8.90 MEGAHERTZ BLANK AND 9.60 MEGAHERTZ BLANK
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK
INPUT TERMINAL IDENTIFICATIONSMA
INPUT TERMINAL MANUFACTURER CODE94990
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK
OUTPUT TERMINAL IDENTIFICATIONSMA
OUTPUT TERMINAL MANUFACTURER CODE94990
OVERALL HEIGHT0.630 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE-40.0 TO 85.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION9.25 MEGAHERTZ BLANK
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ5.000
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION8.75 MEGAHERTZ BLANK AND 8.90 MEGAHERTZ BLANK AND 9.60 MEGAHERTZ BLANK AND 10.00 MEGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION8.9 MEGAHERTZ BLANK AND 9.6 MEGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.4 BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES