5935-01-068-7801 CONNECTOR BODY,PLUG,ELECTRICAL Index 5930-01-068-7803 SWITCH SECTION,ROTARY

National Stock Number:
5915-01-068-7802

Federal Supply Class:
5915

National Item Identification Number:
010687802

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
GF5080-30B07294GENISCO FILTER CORP
GF5080-30B13050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON


Techincal Specification:
BODY LENGTH6.900 INCHES NOMINAL
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH4.700 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH7.437 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH3.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD OUTPUT 2ND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
OVERALL HEIGHT3.500 INCHES NOMINAL
OVERALL LENGTH7.900 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 4TH RADIO INTERFERENCE 4TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE 2ND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 3RD RADIO INTERFERENCE 3RD FUNCTION
UNTHREADED MOUNTING HOLE DIAMETER0.205 INCHES NOMINAL
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES