5915-01-025-9192 FILTER,RADIO FREQUENCY INTERFERE Index 5930-01-025-9194 SWITCH,PRESSURE

National Stock Number:
5915-01-025-9193

Federal Supply Class:
5915

National Item Identification Number:
010259193

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
2712-0022-00215280NORTHROP GRUMMAN SYSTEMS CORPORATION DIV ES DEFENSIVE SYSTEMS DIVISION
2712-0022-00226916NORTHROP GRUMMAN SYSTEMS CORPORATION
F173650AM43LCR ELECTRONICS, INC
NF2181205245TE CONNECTIVITY CORPORATION


Techincal Specification:
BODY HEIGHT2.063 INCHES MINIMUM AND 2.187 INCHES MAXIMUM
BODY LENGTH3.252 INCHES MINIMUM AND 3.372 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH2.188 INCHES MINIMUM AND 2.312 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.922 INCHES MINIMUM AND 3.954 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL LENGTH5.031 INCHES MAXIMUM
MAXIMUM TEMP RISE25.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION500.0 MILLIVOLTS DC BLANK
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
OPERATING CURRENT RATING PER FUNCTION IN AMPS55.0 BLANK
OPERATING TEMP RANGE-65.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNTHREADED MOUNTING HOLE DIAMETER0.187 INCHES NOMINAL