BODY LENGTH | 7.000 INCHES MAXIMUM |
BODY MATERIAL | METAL |
BODY WIDTH | 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.000 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 7.875 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 THREADED STUD GROUND 3RD FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD OUTPUT 2ND FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD INPUT 1ST FUNCTION |
INCLOSURE TYPE | HERMETICALLY SEALED |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING TEMP RANGE | -55.0 TO 78.0 CELSIUS |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
OVERALL HEIGHT | 2.000 INCHES MAXIMUM |
OVERALL LENGTH | 9.000 INCHES MAXIMUM |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 600.0 VOLTS AT SEA LEVEL |
MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
MAXIMUM TEMP RISE | 45.0 CELSIUS |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 14.3 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 14.3 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 14.3 3RD RADIO INTERFERENCE 3RD FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
UNPACKAGED UNIT WEIGHT | 6.000 POUNDS NOMINAL |
UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES MINIMUM AND 0.224 INCHES MAXIMUM |