8405-01-013-7247 TROUSERS,MEN'S Index 8405-01-013-7249 TROUSERS,MEN'S

National Stock Number:
5915-01-013-7248

Federal Supply Class:
5915

National Item Identification Number:
010137248

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
519640-164547HONEYWELL INTERNATIONAL, INC
519640-170210HONEYWELL INTERNATIONAL INC.
RF0923713619EMS DEVELOPMENT CORPORATION
RF923713619EMS DEVELOPMENT CORPORATION


Techincal Specification:
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.800 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.300 INCHES NOMINAL
BODY HEIGHT1.350 INCHES MAXIMUM
BODY LENGTH3.330 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH2.830 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY6 WIRE HOOK INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY6 WIRE HOOK OUTPUT 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS 1ST RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS 2ND RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS 3RD RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS 4TH RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS 5TH RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS 6TH RADIO INTERFERENCE
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATION394-007-9002
INPUT TERMINAL MANUFACTURER CODE70210
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 5TH RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 6TH RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM VOLTAGE DROP PER FUNCTION1.3 VOLTS AC 1ST RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION1.3 VOLTS AC 2ND RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION1.3 VOLTS AC 3RD RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION1.3 VOLTS AC 4TH RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION1.3 VOLTS AC 5TH RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION1.3 VOLTS AC 6TH RADIO INTERFERENCE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
NOMINAL THREAD SIZE0.138 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.5 3RD RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.5 6TH RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS16.0 1ST RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS16.0 2ND RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS16.0 4TH RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS16.0 5TH RADIO INTERFERENCE
OPERATING TEMP RANGE-55.0/+85.0 DEG CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OUTPUT TERMINAL IDENTIFICATION394-007-9002
OUTPUT TERMINAL MANUFACTURER CODE70210
OVERALL HEIGHT1.350 INCHES MAXIMUM
OVERALL LENGTH3.630 INCHES MAXIMUM
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 2ND RADIO INTERFERENCE
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 3RD RADIO INTERFERENCE
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 1ST RADIO INTERFERENCE
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 4TH RADIO INTERFERENCE
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 5TH RADIO INTERFERENCE
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 6TH RADIO INTERFERENCE
SPECIAL FEATURES3.130 IN. W MAX INCL TERMINALS
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES