4820-01-003-6015 VALVE,CHECK Index 5915-01-003-6018 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-003-6017

Federal Supply Class:
5915

National Item Identification Number:
010036017

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
106348-10006481NORTHROP GRUMMAN SYSTEMS CORPORATION
106348-10013973LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION


Techincal Specification:
BODY MATERIALMETAL
BODY LENGTH4.000 INCHES NOMINAL
BODY WIDTH2.750 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.000 INCHES NOMINAL
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL HEIGHT1.280 INCHES MAXIMUM
OVERALL LENGTH23.000 INCHES NOMINAL
MAXIMUM VOLTAGE DROP PER FUNCTION1.1 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.1 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.1 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.164 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS4.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS4.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS4.0 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES