AVERAGE LIFE RATING IN HOURS | 2000.0 |
BODY HEIGHT | 2.610 INCHES MINIMUM AND 2.640 INCHES MAXIMUM |
BODY LENGTH | 2.297 INCHES MINIMUM AND 2.327 INCHES MAXIMUM |
BODY WIDTH | 1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.735 INCHES MINIMUM AND 1.765 INCHES MAXIMUM |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 40.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK 1ST FUNCTION |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.110 INCHES MINIMUM AND 1.140 INCHES MAXIMUM |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET INPUT 1ST FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET GROUND 3RD FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET OUTPUT 2ND FUNCTION |
FREQUENCY BAND WIDTH PER FUNCTION | 400.00 HERTZ BLANK AND 425.00 HERTZ BLANK |
INCLOSURE TYPE | ENCASED |
INPUT IMPEDANCE PER FUNCTION W/LOAD | 600.0 OHMS BLANK |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 8.0 BLANK |
OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 8.0 KILOHMS BLANK |
OVERALL HEIGHT | 2.954 INCHES MINIMUM AND 3.040 INCHES MAXIMUM |
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 500.0 VOLTS AT SEA LEVEL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.138 INCHES |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
REFERENCE FREQUENCY PER FUNCTION | 775.0 HERTZ BLANK |
VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 2000.0 |
SPECIFICATION/STANDARD DATA | 81349-MIL-F-18327/15 GOVERNMENT SPECIFICATION |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 300.00 HERTZ BLANK AND 400.00 HERTZ BLANK AND 425.00 HERTZ BLANK |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
TEST DATA DOCUMENT | 81349-MIL-F-18327 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |