5950-00-978-2641 COIL Index 5915-00-978-2643 FILTER ASSEMBLY

National Stock Number:
5915-00-978-2642

Federal Supply Class:
5915

National Item Identification Number:
009782642

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
C11148-1309269OMEX


Techincal Specification:
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 1ST BAND PASS 1ST FUNCTION AND 40.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 2ND BAND PASS 2ND FUNCTION AND 40.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.656 INCHES NOMINAL
BODY HEIGHT3.375 INCHES NOMINAL
BODY LENGTH3.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.688 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN OUTPUT 2ND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 PIN GROUND 3RD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION14.455 KILOHERTZ 1ST BAND PASS AND 14.545 KILOHERTZ 1ST BAND PASS
FREQUENCY BAND WIDTH PER FUNCTION14.455 KILOHERTZ 2ND BAND PASS AND 14.545 KILOHERTZ 2ND BAND PASS
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND PASS
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND PASS
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST BAND PASS
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND BAND PASS
INCLOSURE TYPEHERMETICALLY SEALED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST BAND PASS 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND BAND PASS 2ND FUNCTION
PROPRIETARY CHARACTERISTICSPACS
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE-55.0/+85.0 DEG CELSIUS
OVERALL HEIGHT3.625 INCHES NOMINAL
REFERENCE FREQUENCY PER FUNCTION14.5 SINGLE RADIO INTERFERENCE PULSES PER SECOND
REFERENCE FREQUENCY PER FUNCTION14.5 SINGLE RADIO INTERFERENCE TWO PHASE TO TWO PHASE
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST BAND PASS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND BAND PASS
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION14.41 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 14.455 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 14.545 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 14.59 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION14.41 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 14.455 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 14.545 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 14.59 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial