1220-00-975-9868 REEL Index 1220-00-975-9871 STANDOFF,KEY

National Stock Number:
5915-00-975-9870

Federal Supply Class:
5915

National Item Identification Number:
009759870

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
905120-106481NORTHROP GRUMMAN SYSTEMS CORPORATION
GF-690007294GENISCO FILTER CORP
GF-690013050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON


Techincal Specification:
BODY HEIGHT0.410 INCHES NOMINAL
BODY LENGTH0.789 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.390 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.03 AND 0.05 AND 1.0 AND 5.0 AND 10.0 AND 20.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS6.0 AND 10.0 AND 20.0 AND 60.0 AND 45.0 AND 30.0
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONA4549
INPUT TERMINAL MANUFACTURER CODE83241
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
OUTPUT TERMINAL IDENTIFICATIONA4549
OUTPUT TERMINAL MANUFACTURER CODE83241
OVERALL HEIGHT0.720 INCHES MAXIMUM
MAXIMUM VOLTAGE DROP PER FUNCTION300.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION300.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
MAXIMUM TEMP RISE30.0 CELSIUS
MOUNTING FACILITY TYPE AND QUANTITY1 CLAMP
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.8 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.8 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING TEMP RANGE-55.0 TO 95.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION100.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION100.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
UNPACKAGED UNIT WEIGHT2.000 OUNCES NOMINAL
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0