5915-00-811-1127 FILTER,BAND PASS Index 5975-00-811-1130 BOOT,DUST AND MOISTURE SEAL

National Stock Number:
5915-00-811-1128

Federal Supply Class:
5915

National Item Identification Number:
008111128

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
77C703679P103538LOCKHEED MARTIN CORPORATION
77C703679P124446GENERAL ELECTRIC COMPANY
S8232609376OMNITEC DATA CORP SUB OF NYTRONICS INC


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
BODY HEIGHT4.000 INCHES NOMINAL
BODY LENGTH2.500 INCHES NOMINAL
BODY WIDTH2.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.906 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 NOMINAL BLANK AND 3.0 NOMINAL BLANK 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.688 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION550.00 HERTZ BLANK AND 1.05 KILOHERTZ BLANK
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 KILOHMS BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS8.0 BLANK
LOAD IMPEDANCE PER FUNCTION1.0 MEGOHMS BLANK
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT1.0 MEGOHMS BLANK
OVERALL HEIGHT4.312 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 KILOHMS BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-RESISTANCE BLANK
REFERENCE FREQUENCY PER FUNCTION800.0 HERTZ BLANK
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION150.00 HERTZ BLANK AND 550.00 HERTZ BLANK AND 1.05 KILOHERTZ BLANK AND 2.75 KILOHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE