Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
241-8008-0095104ALCATEL-LUCENT HOLDINGS INC.
241-8008-00013499ROCKWELL COLLINS, INC.
241-8008-00095104ALCATEL-LUCENT HOLDINGS INC.
5004-003313050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON


Techincal Specification:
AVERAGE LIFE RATING IN HOURS250.0
BODY HEIGHT1.469 INCHES MAXIMUM
BODY LENGTH1.031 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.906 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.625 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL HEIGHT2.189 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE800.0 VOLTS AT SEA LEVEL
MAXIMUM TEMP RISE25.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION750.0 MILLIVOLTS DC BLANK
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 BLANK
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION130.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES