6130-00-695-9340 RECTIFIER,METALLIC Index 5950-00-695-9345 REACTOR

National Stock Number:
5915-00-695-9342

Federal Supply Class:
5915

National Item Identification Number:
006959342

Description:
FILTER,BAND SUPPRESSION

Detail:
AN ITEM DESIGNED TO SUPPRESS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO PASS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).


Manufacturer Information:
2718282340L3HARRIS TECHNOLOGIES, INC.


Techincal Specification:
BODY HEIGHT2.750 INCHES NOMINAL
BODY LENGTH1.750 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.750 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MAXIMUM 2ND BAND SUPPRESSION AND 40.0 MINIMUM 2ND BAND SUPPRESSION 2ND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MAXIMUM 1ST BAND SUPPRESSION AND 40.0 MINIMUM 1ST BAND SUPPRESSION 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.250 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION120.00 HERTZ 2ND BAND SUPPRESSION AND 280.00 HERTZ 2ND BAND SUPPRESSION 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION60.00 HERTZ 1ST BAND SUPPRESSION AND 240.00 HERTZ 1ST BAND SUPPRESSION 1ST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD10.0 KILOHMS 1ST BAND SUPPRESSION 1ST FUNCTION
INPUT IMPEDANCE PER FUNCTION W/LOAD10.0 KILOHMS 2ND BAND SUPPRESSION 2ND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS6.0 1ST BAND SUPPRESSION 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS6.0 2ND BAND SUPPRESSION 2ND FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT1.0 MEGOHMS 1ST BAND SUPPRESSION 1ST FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT1.0 MEGOHMS 2ND BAND SUPPRESSION 2ND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
REFERENCE FREQUENCY PER FUNCTION150.0 HERTZ 1ST BAND SUPPRESSION 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION190.0 HERTZ 2ND BAND SUPPRESSION 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 HERTZ 1ST BAND SUPPRESSION AND 60.00 HERTZ 1ST BAND SUPPRESSION AND 240.00 HERTZ 1ST BAND SUPPRESSION AND 20.00 KILOHERTZ 1ST BAND SUPPRESSION 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 HERTZ 2ND BAND SUPPRESSION AND 120.00 HERTZ 2ND BAND SUPPRESSION AND 280.00 HERTZ 2ND BAND SUPPRESSION AND 20.00 KILOHERTZ 2ND BAND SUPPRESSION 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE