5365-00-678-0176 SPACER,SLEEVE Index 5360-00-678-0181 SPRING,HELICAL,COMPRESSION

National Stock Number:
5915-00-678-0177

Federal Supply Class:
5915

National Item Identification Number:
006780177

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
222294328527L3HARRIS TECHNOLOGIES, INC.
97JX12213619EMS DEVELOPMENT CORPORATION
C222294328527L3HARRIS TECHNOLOGIES, INC.


Techincal Specification:
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH6.734 INCHES MINIMUM AND 6.766 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.469 INCHES MINIMUM AND 1.531 INCHES MAXIMUM
BODY HEIGHT3.376 INCHES MINIMUM AND 3.500 INCHES MAXIMUM
BODY LENGTH8.563 INCHES MINIMUM AND 8.627 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.562 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONGS02-22-22P-111
INPUT TERMINAL MANUFACTURER CODE71468
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 1ST RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 2ND RADIO INTERFERENCE
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 1ST RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 2ND RADIO INTERFERENCE
OPERATING TEMP RANGE-28.0/+85.0 DEG CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNTHREADED MOUNTING HOLE DIAMETER0.188 INCHES NOMINAL


Click here to Register for Free 30-day Trial