5950-00-677-0834 TRANSFORMER,POWER Index 5910-00-677-0837 CAPACITORVARIABLEAI

National Stock Number:
5915-00-677-0835

Federal Supply Class:
5915

National Item Identification Number:
006770835

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
328C046H0179500WESTINGHOUSE ELECTRIC CORP
328C046H0197942NORTHROP GRUMMAN SYSTEMS CORPORATION
98JX40A13619EMS DEVELOPMENT CORPORATION
98JX40A56289SPRAGUE ELECTRIC CO WORLD HQS
NF10679-293790CORNELL-DUBILIER ELECTRONICS, INC.


Techincal Specification:
BODY MATERIALMETAL
BODY LENGTH6.078 INCHES NOMINAL
BODY SURFACE TREATMENTTIN
BODY WIDTH2.859 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH6.703 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.859 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB W/SCREW INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB W/SCREW OUTPUT 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION440.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION440.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION440.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OVERALL HEIGHT2.312 INCHES NOMINAL
OVERALL LENGTH6.578 INCHES NOMINAL
OVERALL WIDTH3.983 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
OPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE 2ND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 3RD RADIO INTERFERENCE 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNTHREADED MOUNTING HOLE DIAMETER0.196 INCHES NOMINAL


Click here to Register for Free 30-day Trial