5915-00-163-6535 FILTER,BAND PASS Index 5915-00-163-6537 FILTER,LOW PASS

National Stock Number:
5915-00-163-6536

Federal Supply Class:
5915

National Item Identification Number:
001636536

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
247AS-C0114-02330003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
3B120-150/10-0/0P50140K&L MICROWAVE LLC
4BC150/10-KL23042TRILITHIC, INC.


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION18.0 WATTS BLANK
BODY MATERIALALUMINUM
BODY OUTSIDE DIAMETER0.450 INCHES MINIMUM AND 0.550 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FEATURES PROVIDEDNUT
FREQUENCY BAND WIDTH PER FUNCTION145.00 MEGAHERTZ BLANK AND 155.00 MEGAHERTZ BLANK
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONMIL-C-39012
INPUT TERMINAL MANUFACTURER CODE30003
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OUTPUT TERMINAL IDENTIFICATIONMIL-C-39012
OUTPUT TERMINAL MANUFACTURER CODE30003
OVERALL LENGTH4.950 INCHES MINIMUM AND 5.050 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.250 INCHES
OPERATING TEMP RANGE+0.0 TO 85.0 CELSIUS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
REFERENCE FREQUENCY PER FUNCTION150.0 MEGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION131.00 MEGAHERTZ BLANK AND 145.00 MEGAHERTZ BLANK AND 155.00 MEGAHERTZ BLANK AND 169.00 MEGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION145.0 MEGAHERTZ BLANK AND 155.0 MEGAHERTZ BLANK
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 55.0


Click here to Register for Free 30-day Trial