5961-00-163-3911 TRANSISTOR Index 5950-00-163-3914 TRANSFORMER,POWER

National Stock Number:
5915-00-163-3912

Federal Supply Class:
5915

National Item Identification Number:
001633912

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
5JX390156289SPRAGUE ELECTRIC CO WORLD HQS
5JX3901A56289SPRAGUE ELECTRIC CO WORLD HQS
PA-AA11M-030T50056PIEZOTHERMX CORPORATION
SM-C-5362688-204YE2VALCORE MANUFACTURING LLC
SM-C-5362688-220723VALCORE MANUFACTURING LLC
SM-C-586288-280063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY LENGTH0.550 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.375 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.3 AND 1.0 AND 10.0 AND 100.0 AND 1000.0 AND 10000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS10.0 AND 40.0 AND 80.0
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL LENGTH1.355 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE370.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING 3RD FUNCTION
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.250 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 BLANK
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC BLANK AND 185.0 VOLTS DC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0


Click here to Register for Free 30-day Trial