5930-00-156-0086 SWITCH,ROTARY Index 5110-00-156-0089 FILE,HAND

National Stock Number:
5915-00-156-0088

Federal Supply Class:
5915

National Item Identification Number:
001560088

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
95G3253-113050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
95G3253-156289SPRAGUE ELECTRIC CO WORLD HQS
95G3253-156528FIL-COIL INTERNATIONAL LLC
95G3253-1-167177ZENITH ELECTRONICS CORPORATION
95G3253-1-198738HERLEY CHICAGO DBA STEWART WARNER ELECTRONICS
FC54356528FIL-COIL INTERNATIONAL LLC
RF1061713619EMS DEVELOPMENT CORPORATION


Techincal Specification:
BODY HEIGHT2.000 INCHES NOMINAL
BODY LENGTH3.500 INCHES NOMINAL
BODY SURFACE TREATMENTTIN
BODY WIDTH1.375 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.000 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY5 TURRET OUTPUT 2ND FUNCTION
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONMS3112E128P
INPUT TERMINAL MANUFACTURER CODE96906
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING TEMP RANGE-54.0 TO 90.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION132.0 VOLTS AC 2ND RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION132.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION132.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION132.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION132.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION
OVERALL HEIGHT2.876 INCHES NOMINAL
OVERALL LENGTH3.938 INCHES NOMINAL
MAXIMUM VOLTAGE DROP PER FUNCTION1.5 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.5 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.5 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION4.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION4.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY2 SLOT 1ST FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE 2ND FUNCTION
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING SLOT WIDTH0.140 INCHES NOMINAL
NOMINAL THREAD SIZE0.112 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.05 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.05 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.05 5TH RADIO INTERFERENCE 5TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 4TH RADIO INTERFERENCE 4TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 5TH RADIO INTERFERENCE 5TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
SPECIAL FEATURESONE GROUND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0