ELECTRICAL POLARIZATION | POLARIZED |
BODY DIAMETER | 0.120 INCHES MINIMUM AND 0.151 INCHES MAXIMUM |
BODY LENGTH | 0.255 INCHES MINIMUM AND 0.317 INCHES MAXIMUM |
BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
CAPACITANCE VALUE PER SECTION | 0.680 MICROFARADS SINGLE SECTION |
CASE INSULATION MATERIAL | PLASTIC |
CASE MATERIAL | METAL |
CRITICALITY CODE JUSTIFICATION | FEAT |
DC LEAKAGE AT MAXIMUM OPERATING TEMP | 4.0 MICROAMPERES |
DC LEAKAGE AT REFERENCE TEMP | 0.300 MICROAMPERES |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.000 |
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS | 2.10 |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-4 |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 75.0 DC SINGLE SECTION |
NONDERATED OPERATING TEMP | -55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
RELIABILITY INDICATOR | ESTABLISHED |
SCHEMATIC DIAGRAM DESIGNATOR | ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
SPECIAL FEATURES | WEIBULL GRADED FAILURE RATE |
SPECIFICATION/STANDARD DATA | 81349-MIL-C-39003/10 GOVERNMENT SPECIFICATION |
TERMINAL DIAMETER | 0.018 INCHES MINIMUM AND 0.022 INCHES MAXIMUM |
TERMINAL LENGTH | 1.250 INCHES MINIMUM AND 1.750 INCHES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
TEST DATA DOCUMENT | 81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
TOLERANCE RANGE PER SECTION | -10.00 TO 10.00 PERCENT SINGLE SECTION |