5910-01-354-0211 CAPACITOR,FIXED,CERAMIC DIELECTR Index 5910-01-354-0213 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-01-354-0212

Federal Supply Class:
5910

National Item Identification Number:
013540212

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CDR03BX153BKYS81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-55681/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-55681/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.020 INCHES MINIMUM AND 0.080 INCHES MAXIMUM
BODY LENGTH0.165 INCHES MINIMUM AND 0.195 INCHES MAXIMUM
BODY WIDTH0.065 INCHES MINIMUM AND 0.095 INCHES MAXIMUM
BODY STYLECHIP TYPE
CAPACITANCE VALUE PER SECTION15000.000 PICOFARADS SINGLE SECTION
CASE MATERIALCERAMIC
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.500
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP1000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP10000.0 MEGOHMS
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-25.0 TO 15.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION
SPECIFICATION/STANDARD DATA81349-MIL-C-55681/1 GOVERNMENT SPECIFICATION
TERMINAL LENGTH0.010 INCHES MINIMUM AND 0.030 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY2 BONDING PAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-55681 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION