4320-01-165-6872 ROD,CONNECTING,PUMP Index 5910-01-165-6874 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-01-165-6873

Federal Supply Class:
5910

National Item Identification Number:
011656873

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
0N28869998230NATIONAL SECURITY AGENCY


Techincal Specification:
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.1500
BODY HEIGHT0.020 INCHES MINIMUM AND 0.055 INCHES MAXIMUM
BODY LENGTH0.080 INCHES NOMINAL
BODY STYLECHIP TYPE
BODY WIDTH0.050 INCHES NOMINAL
CAPACITANCE VALUE PER SECTION120.000 PICOFARADS SINGLE SECTION
CASE MATERIALCERAMIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.060 INCHES NOMINAL
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP1000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
PROPRIETARY CHARACTERISTICSPACS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.000
RELIABILITY INDICATORESTABLISHED
SPECIFICATION/STANDARD DATA81349-MIL-C-55681D/2G GOVERNMENT SPECIFICATION
SPECIAL FEATURESSELECTED ITEM
TERMINAL LENGTH0.010 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 BONDING PAD
TEST DATA DOCUMENT81349-MIL-C-55681B/1A SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). AND 98230-0N288699 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TOLERANCE RANGE PER SECTION-1.00/+1.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial