5910-01-068-2207 CAPACITOR,FIXED,PLA Index 5910-01-068-2209 CAPACITOR,FIXED,MICA DIELECTRIC

National Stock Number:
5910-01-068-2208

Federal Supply Class:
5910

National Item Identification Number:
010682208

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CE35C300R81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC6281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
BODY DIAMETER1.437 INCHES NOMINAL
BODY LENGTH3.562 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINAL(S) ON ONE END
CAPACITIVE ELECTRODE MATERIALALUMINUM
CAPACITANCE VALUE PER SECTION300.000 MICROFARADS ALL SECTIONS
CASE INSULATION MATERIALPLASTIC
CASE MATERIALMETAL
DC LEAKAGE AT REFERENCE TEMP174.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT17.0000
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS1100.0
NONDERATED OPERATING TEMP-40.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION400.0 DC ALL SECTIONS
POWER FACTOR AT REFERENCE TEMP IN PERCENT4.0000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
SECTION QUANTITY2
SPECIFICATION/STANDARD DATA81349-MIL-C-62/4 GOVERNMENT SPECIFICATION
TERMINAL LENGTH0.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-62 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 50.00 PERCENT ALL SECTIONS