5910-01-067-5389 CAPACITOR,FIXED,MICA DIELECTRIC Index 5910-01-067-5391 CAPACITOR,FIXED,MICA DIELECTRIC

National Stock Number:
5910-01-067-5390

Federal Supply Class:
5910

National Item Identification Number:
010675390

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
159101512-05027014NATIONAL SEMICONDUCTOR CORPORATION
1801C0G050A221J26654VARADYNE INDUSTRIES INC
23195-027119397BAE SYSTEMS INFORMATION & ELECTRONIC SYSTEMS INTEGRATION INC.
292CC0G221J050B56289SPRAGUE ELECTRIC CO WORLD HQS
403849-5330003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
5910PL03170299009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
945833-383406481NORTHROP GRUMMAN SYSTEMS CORPORATION
C13A221K72982ERIE SPECIALTY PRODUCTS INC
CAC02C0G221K100A16299AVX CORP RALEIGH PLANT
CCR75CG221GM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CCR75CG221GP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CCR75CG221GR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CCR75CG221JM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CCR75CG221JR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CCR75CG221KM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CCR77CG221GM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-20/2781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-20/2781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC0020-2781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
SA105A221KAAK8295AVX LTD
SA105A221KAAU2109AVX LTD
SM-B-65095680063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
WM11BY221U96733SFE TECHNOLOGIES


Techincal Specification:
BODY DIAMETER0.090 INCHES NOMINAL
BODY LENGTH0.160 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION220.000 PICOFARADS SINGLE SECTION
CASE MATERIALPLASTIC
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.1500
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP10000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.0100
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIFICATION/STANDARD DATA81349-MIL-C-20/27 GOVERNMENT SPECIFICATION
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS0.0 SINGLE SECTION
TERMINAL DIAMETER0.015 INCHES MINIMUM AND 0.027 INCHES MAXIMUM
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-20 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS-30.0 TO 30.0 SINGLE SECTION
TOLERANCE RANGE PER SECTION-2.00 TO 2.00 PERCENT SINGLE SECTION