5945-01-065-3950 RELAY,ELECTROMAGNETIC Index 5905-01-065-3952 RESISTOR,FIXED,WIRE WOUND

National Stock Number:
5910-01-065-3951

Federal Supply Class:
5910

National Item Identification Number:
010653951

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
CQR29A3MC184G3P81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-19978/1381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC19978-1381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY DIAMETER0.462 INCHES MAXIMUM
BODY LENGTH1.031 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION0.180 MICROFARADS SINGLE SECTION
CASE INSULATION MATERIALPLASTIC
CASE MATERIALMETAL
DIELECTRIC MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.6000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INTERNAL ELECTRICAL CONNECTION TYPEEXTENDED FOIL
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP25000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
NONDERATED OPERATING TEMP-65.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION200.0 DC SINGLE SECTION
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.1000
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
SPECIFICATION/STANDARD DATA81349-MIL-C-19978/13 GOVERNMENT SPECIFICATION
TERMINAL DIAMETER0.032 INCHES NOMINAL
TERMINAL LENGTH1.625 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-19978 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-2.00 TO 2.00 PERCENT SINGLE SECTION