5970-01-064-4694 INSULATOR,WASHER Index 5910-01-064-4696 CAPACITOR,FIXED,PLASTIC DIELECTR

National Stock Number:
5910-01-064-4695

Federal Supply Class:
5910

National Item Identification Number:
010644695

Description:
CAPACITOR,FIXED,GLASS DIELECTRIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a glass (silicas) or glass like substance (e.g., porcelain, vitreous enamel) as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
3522 500 07879H0203THALES NEDERLAND B.V.
CY06C331G81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-11272/1381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.115 INCHES NOMINAL
BODY LENGTH0.300 INCHES NOMINAL
BODY WIDTH0.200 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
CAPACITANCE VALUE PER SECTION330.000 PICOFARADS SINGLE SECTION
CASE MATERIALGLASS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.200 INCHES NOMINAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0010
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION300.0 DC SINGLE SECTION
QUALITY FACTOR AT REFERENCE TEMP1000.0000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS140.0 SINGLE SECTION
TERMINAL DIAMETER0.020 INCHES NOMINAL
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-11272/13 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS-25.0 TO 25.0 SINGLE SECTION
TOLERANCE RANGE PER SECTION-2.00 TO 2.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial