5910-01-061-1841 CAPACITOR,FIXED,CERAMIC DIELECTR Index 5910-01-061-1843 CAPACITOR,FIXED,CERAMIC DIELECTR

National Stock Number:
5910-01-061-1842

Federal Supply Class:
5910

National Item Identification Number:
010611842

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
224757-04281413BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
860653-5806481NORTHROP GRUMMAN SYSTEMS CORPORATION
CK32BV104KTX81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CKR32BV104KM16299AVX CORP RALEIGH PLANT
M39014-21-009081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39014/21-008981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39014C/21-008916299AVX CORP RALEIGH PLANT
MIL-C-39014/2181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39014C/2181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39014/2181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY DIAMETER0.120 INCHES MINIMUM AND 0.140 INCHES MAXIMUM
BODY LENGTH0.230 INCHES MINIMUM AND 0.250 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION0.100 MICROFARADS SINGLE SECTION
CASE MATERIALPLASTIC
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT3.0000
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP10000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-50.0 TO 20.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION
SPECIFICATION/STANDARD DATA81349-MIL-C-39014/21 GOVERNMENT SPECIFICATION
TERMINAL DIAMETER0.015 INCHES MINIMUM AND 0.019 INCHES MAXIMUM
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-39014 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial