5895-01-031-2038 PREAMP Index 5962-01-031-2041 MICROCIRCUIT

National Stock Number:
5910-01-031-2040

Federal Supply Class:
5910

National Item Identification Number:
010312040

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
5104-032621877NORTHROP GRUMMAN SYSTEMS CORPORATION
5104-03263NBG8NAVAL RESEARCH LABORATORY
5104-032681995NAVAL RESEARCH LABORATORY
5104-032688898THE JOHNS HOPKINS UNIVERSITY APPLIED PHYSICS LABORATORY LLC
5104-032721877NORTHROP GRUMMAN SYSTEMS CORPORATION
5104-03273NBG8NAVAL RESEARCH LABORATORY
5104-032781995NAVAL RESEARCH LABORATORY


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY DIAMETER0.170 INCHES MINIMUM AND 0.201 INCHES MAXIMUM
BODY LENGTH0.443 INCHES MINIMUM AND 0.505 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION22.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
CASE INSULATION MATERIALPLASTIC
CASE MATERIALMETAL
DC LEAKAGE AT MAXIMUM OPERATING TEMP40.0 MICROAMPERES
DC LEAKAGE AT REFERENCE TEMP2.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT6.000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-4
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION15.0 DC SINGLE SECTION
PRECIOUS MATERIAL AND LOCATIONCARRIER STRIP CONTACT AND TERMINAL SURFACES GOLD
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
SPECIAL FEATURESCAPACITOR MOUNTED ON A PLASTIC CARRIER STRIP; CARRIER STRIP MATERIAL THERMOPLASTIC POLYESTER,UL RATED 94V-0; CONTACT AND TERMINAL MATERIAL PHOSPOR BRONZE WITH GOLD OVER NICKEL PLATING
TERMINAL DIAMETER0.018 INCHES MINIMUM AND 0.022 INCHES MAXIMUM
TERMINAL LENGTH1.250 INCHES MINIMUM AND 1.750 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION