5910-01-016-1105 CAPACITOR,FIXED,MICA DIELECTRIC Index 5910-01-016-1107 CAPACITOR,FIXED,MICA DIELECTRIC

National Stock Number:
5910-01-016-1106

Federal Supply Class:
5910

National Item Identification Number:
010161106

Description:
CAPACITOR,FIXED,MICA DIELECTRIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CM07FD153J0381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-5/1881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.320 INCHES NOMINAL
BODY LENGTH0.760 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY WIDTH1.031 INCHES MAXIMUM
CAPACITANCE VALUE PER SECTION15000.000 PICOFARADS SINGLE SECTION
CASE MATERIALPLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.425 INCHES NOMINAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0010
INSULATION RESISTANCE AT REFERENCE TEMP1000.0 MEGOHM-MICROFARADS
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS+0.0 TO 70.0 SINGLE SECTION
TERMINAL DIAMETER0.040 INCHES NOMINAL
TERMINAL LENGTH1.000 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-5/18 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial