5910-01-016-0054 CAPACITOR,FIXED,PLASTIC DIELECTR Index 5910-01-016-0057 CAPACITOR,FIXED,PLASTIC DIELECTR

National Stock Number:
5910-01-016-0056

Federal Supply Class:
5910

National Item Identification Number:
010160056

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
05TC981BSN12517COMPONENT RESEARCH CO INC
247AS-C0249-02330003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
C11B981BSN12517COMPONENT RESEARCH CO INC


Techincal Specification:
BODY DIAMETER0.245 INCHES NOMINAL
BODY LENGTH0.687 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION980.000 PICOFARADS SINGLE SECTION
CASE INSULATION MATERIALPLASTIC
CASE MATERIALMETAL
DIELECTRIC MATERIALPLASTIC POLYCARBONATE
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0300
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INTERNAL ELECTRICAL CONNECTION TYPEEXTENDED FOIL
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP25000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP250000.0 MEGOHMS
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-2
NONDERATED OPERATING TEMP-62.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-0.25 TO 0.25 PERCENT SINGLE SECTION