5910-00-998-9213 CAPACITOR,FIXED,PLASTIC DIELECTR Index 5910-00-998-9215 CAPACITOR,FIXED,CERAMIC DIELECTR

National Stock Number:
5910-00-998-9214

Federal Supply Class:
5910

National Item Identification Number:
009989214

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
192P5635R856289SPRAGUE ELECTRIC CO WORLD HQS
192P5639R856289SPRAGUE ELECTRIC CO WORLD HQS
215095-067306KW9LUCENT TECHNOLOGIES INC DBA FEDERAL MARKETING GROUP
219095-067306KW9LUCENT TECHNOLOGIES INC DBA FEDERAL MARKETING GROUP
219095-067314028SYPRIS ELECTRONICS, LLC
80325907342NAI TECHNOLOGIES INC
8032590VGU1NORTH ATLANTIC INDUSTRIES, INC.


Techincal Specification:
BODY DIAMETER0.225 INCHES NOMINAL
BODY LENGTH0.655 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION56000.000 PICOFARADS SINGLE SECTION
CASE MATERIALPLASTIC
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
INSULATION RESISTANCE AT REFERENCE TEMP50000.0 MEGOHM-MICROFARADS
INTERNAL ELECTRICAL CONNECTION TYPEEXTENDED FOIL
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION80.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL DIAMETER0.032 INCHES NOMINAL
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial