5910-00-998-6938 CAPACITOR,FIXED,CERAMIC DIELECTR Index 5910-00-998-6940 CAPACITOR,FIXED,CERAMIC DIELECTR

National Stock Number:
5910-00-998-6939

Federal Supply Class:
5910

National Item Identification Number:
009986939

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
0600736D0894ROHDE & SCHWARZ GMBH & CO. KOMMANDITGESELLSCHAFT
2432850G2328527L3HARRIS TECHNOLOGIES, INC.
2432850G2328528ITT INDUSTRIES INC ITT AEROSPACE COMMUNICATIONS DIV EAST
4299728896D8385THALES DEUTSCHLAND GMBH
5800583-454019-309C0426HENSOLDT SENSORS GMBH
5801515-8188D1839BUNDESAMT FUER AUSRUESTUNG,
8123-000C0G0-470J72982ERIE SPECIALTY PRODUCTS INC
8123-100C0G470J72982ERIE SPECIALTY PRODUCTS INC
8123-100C0G470JC0151MURATA ELEKTRONIK GMBH
8123-100COG470K72982ERIE SPECIALTY PRODUCTS INC
CC0600736D0894ROHDE & SCHWARZ GMBH & CO. KOMMANDITGESELLSCHAFT
V2051-Z6047-J2S3120SIEMENS SCHWEIZ AG DBA SIEMENS SWITZERLAND LTD.


Techincal Specification:
BODY HEIGHT0.100 INCHES NOMINAL
BODY LENGTH0.200 INCHES NOMINAL
BODY WIDTH0.200 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
CAPACITANCE VALUE PER SECTION47.000 PICOFARADS SINGLE SECTION
CASE MATERIALPLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.190 INCHES MINIMUM AND 0.210 INCHES MAXIMUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.2000
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-5.0 TO 5.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS0.0 SINGLE SECTION
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT28528-2432850G23 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS-30.0 TO 30.0 SINGLE SECTION
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial