5930-00-989-9711 SWITCH,TOGGLE Index 5910-00-989-9715 CAPACITOR,VARIABLE,GLASS DIELECT

National Stock Number:
5910-00-989-9712

Federal Supply Class:
5910

National Item Identification Number:
009899712

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CC52LH560G81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-20/1881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC20-1881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY DIAMETER0.550 INCHES NOMINAL
BODY LENGTH0.120 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, RADIAL TERMINALS
CAPACITANCE VALUE PER SECTION56.000 PICOFARADS SINGLE SECTION
CASE MATERIALCERAMIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER0.315 INCHES MINIMUM AND 0.435 INCHES MAXIMUM
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP1000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP50000.0 MEGOHMS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
QUALITY FACTOR AT REFERENCE TEMP1000.0000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS-80.0 SINGLE SECTION
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-20 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS-60.0 TO 60.0 SINGLE SECTION
TOLERANCE RANGE PER SECTION-2.00 TO 2.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial