5910-00-811-8199 CAPACITOR,FIXED,CERAMIC DIELECTR Index 5910-00-811-8201 CAPACITOR,FIXED,CERAMICDIELECTR

National Stock Number:
5910-00-811-8200

Federal Supply Class:
5910

National Item Identification Number:
008118200

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
416977-196214RAYTHEON COMPANY
8133L9BREV5U122K72982ERIE SPECIALTY PRODUCTS INC
CK06BX122K81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC11015-1981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.090 INCHES NOMINAL
BODY LENGTH0.290 INCHES NOMINAL
BODY WIDTH0.290 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
CAPACITANCE VALUE PER SECTION1200.000 PICOFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.185 INCHES MINIMUM AND 0.215 INCHES MAXIMUM
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 150.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION200.0 DC SINGLE SECTION
POWER FACTOR AT REFERENCE TEMP IN PERCENT2.5000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-25.0 TO 15.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-11015 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial