5910-00-810-0689 CAPACITOR,FIXED,PAPER DIELECTRIC Index 5910-00-810-0691 CAPACITOR,FIXED,PAPER DIELECTRIC

National Stock Number:
5910-00-810-0690

Federal Supply Class:
5910

National Item Identification Number:
008100690

Description:
CAPACITOR,FIXED,PAPER DIELECTRIC

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having paper as the dielectric material. It may be a single unit or consist of two or more fixed units which cannot be seperated. For items whose dielectric material consist of plasticized (plastic impregnated) paper or paper-plastic combinations, see CAPACITOR, FIXED, PLASTIC DIELECTRIC. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
82111965597THALES USA, INC.
8563755-00424617GENERAL MOTORS CORP
CP54B1EB405K181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CP54B1FB405V81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-25/481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT1.125 INCHES NOMINAL
BODY LENGTH2.000 INCHES NOMINAL
BODY STYLEW/MTG TABS/FLANGES, TERMINAL(S) ON ONE SURFACE
BODY WIDTH2.000 INCHES NOMINAL
CAPACITANCE VALUE PER SECTION4.000 MICROFARADS SINGLE SECTION
CASE MATERIALMETAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.375 INCHES NOMINAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP20.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP2000.0 MEGOHM-MICROFARADS
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED MOUNTING HOLES
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
UNTHREADED MOUNTING HOLE DIAMETER0.188 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-25 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION