5910-00-809-4881 CAPACITOR,FIXED,ELECTROLYTIC Index 5925-00-809-4883 CIRCUIT BREAKER

National Stock Number:
5910-00-809-4882

Federal Supply Class:
5910

National Item Identification Number:
008094882

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CL21CN040SP381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC396581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPEETCHED FOIL
BODY DIAMETER0.312 INCHES MAXIMUM
BODY LENGTH0.969 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITIVE ELECTRODE MATERIALTANTALUM
CAPACITANCE VALUE PER SECTION4.000 MICROFARADS SINGLE SECTION
CASE INSULATION MATERIALPLASTIC
CASE MATERIALMETAL
DC LEAKAGE AT MAXIMUM OPERATING TEMP14.0 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP2.000 MICROAMPERES
FEATURES PROVIDEDHERMETICALLY SEALED CASE
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS750.0
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION150.0 DC SINGLE SECTION
POWER FACTOR AT REFERENCE TEMP IN PERCENT15.0000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-3965 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-15.00 TO 50.00 PERCENT SINGLE SECTION