5910-00-809-0952 CAPACITOR,FIXED,GLASS DIELECTRIC Index 5910-00-809-0954 CAPACITOR,FIXED,MICA DIELECTRIC

National Stock Number:
5910-00-809-0953

Federal Supply Class:
5910

National Item Identification Number:
008090953

Description:
CAPACITOR,FIXED,GLASS DIELECTRIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a glass (silicas) or glass like substance (e.g., porcelain, vitreous enamel) as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
4112280-22705869RAYTHEON COMPANY
4112280-22782577RAYTHEON COMPANY
CY10C470F81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC11272-181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.172 INCHES NOMINAL
BODY LENGTH0.344 INCHES NOMINAL
BODY WIDTH0.078 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
CAPACITANCE VALUE PER SECTION47.000 PICOFARADS SINGLE SECTION
CASE MATERIALGLASS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0070
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP10000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
QUALITY FACTOR AT REFERENCE TEMP1400.0000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS105.0 SINGLE SECTION
TERMINAL LENGTH1.125 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-11272+1 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS-25.0 TO 25.0 SINGLE SECTION
TOLERANCE RANGE PER SECTION-1.00 TO 1.00 PERCENT SINGLE SECTION