5910-00-674-4796 CAPACITOR,FIXED,ELECTROLYTIC Index 5950-00-674-4799 COIL,RADIO FREQUENCY

National Stock Number:
5910-00-674-4798

Federal Supply Class:
5910

National Item Identification Number:
006744798

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
1049276-106840BENDIX CORP THE
1049276-159364HONEYWELL INTERNATIONAL INC.
1049276-177068ALLIED-SIGNAL INC DBA ALLIED-SIGNAL AEROSPACE CO ELECTRODYNAMICS DIV
165899217BELL INDUSTRIES INC ELECTRONIC DISTRIBUTOR DIV


Techincal Specification:
BODY HEIGHT1.120 INCHES NOMINAL
BODY LENGTH2.120 INCHES NOMINAL
BODY STYLEW/MTG TABS/FLANGES, TERMINAL(S) ON ONE SURFACE
BODY WIDTH2.120 INCHES NOMINAL
CAPACITANCE VALUE PER SECTION1.000 MICROFARADS SINGLE SECTION
DIELECTRIC MATERIALPLASTIC POLYSTYRENE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.500 INCHES NOMINAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0400
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INTERNAL ELECTRICAL CONNECTION TYPEINSERTED TAB
INSULATION RESISTANCE AT REFERENCE TEMP500000.0 MEGOHM-MICROFARADS
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED MOUNTING HOLES
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 65.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION200.0 DC SINGLE SECTION
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS-100.0 SINGLE SECTION
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-0.50 TO 0.50 PERCENT SINGLE SECTION
UNTHREADED MOUNTING HOLE DIAMETER0.190 INCHES NOMINAL


Click here to Register for Free 30-day Trial