5910-00-667-5810 CAPACITOR,FIXED,MICA DIELECTRIC Index 5910-00-667-5815 CAPACITOR,FIXED,MICA DIELECTRIC

National Stock Number:
5910-00-667-5811

Federal Supply Class:
5910

National Item Identification Number:
006675811

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
61584411AMERICAN SHIZUKI CORP
TWMA5P2200853CORNELL-DUBILIER MARKETING INC
TWMA5P2214655CORNELL-DUBILIER ELECTRONICS


Techincal Specification:
BODY DIAMETER0.665 INCHES MINIMUM AND 0.685 INCHES MAXIMUM
BODY LENGTH1.719 INCHES MINIMUM AND 1.781 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION0.050 MICROFARADS SINGLE SECTION
CASE MATERIALMETAL
DIELECTRIC MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.5000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP100.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP50000.0 MEGOHM-MICROFARADS
INTERNAL ELECTRICAL CONNECTION TYPEINSERTED TAB
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL DIAMETER0.032 INCHES NOMINAL
TERMINAL LENGTH1.625 INCHES MINIMUM AND 2.625 INCHES MAXIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial