5910-00-666-7153 CAPACITOR,FIXED,MICA DIELECTRIC Index 5910-00-666-7155 CAPACITOR,FIXED,MICA DIELECTRIC

National Stock Number:
5910-00-666-7154

Federal Supply Class:
5910

National Item Identification Number:
006667154

Description:
CAPACITOR,FIXED,MICA DIELECTRIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
900337418876U S ARMY AVIATION AND MISSILE COMMAND
CM15B680J81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-5/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.300 INCHES NOMINAL
BODY LENGTH0.520 INCHES NOMINAL
BODY WIDTH0.190 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
CAPACITANCE VALUE PER SECTION68.000 PICOFARADS SINGLE SECTION
CASE MATERIALPLASTIC
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0010
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP10000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION300.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIFICATION/STANDARD DATA81349-MIL-C-5/1 GOVERNMENT SPECIFICATION
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.120 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-5 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial