5340-00-546-2984 HOLDER,SPRING Index 5910-00-546-2992 CAPACITOR,FIXED,MICA DIELECTRIC

National Stock Number:
5910-00-546-2991

Federal Supply Class:
5910

National Item Identification Number:
005462991

Description:
CAPACITOR,FIXED,MICA DIELECTRIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
4112310-8405869RAYTHEON COMPANY
CMR07F103G0DM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CMR07F103GODM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CMR07F103J0DM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39001-581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39001/581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.200 INCHES MINIMUM AND 0.340 INCHES MAXIMUM
BODY LENGTH0.700 INCHES MINIMUM AND 0.800 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY WIDTH0.890 INCHES MAXIMUM
CAPACITANCE VALUE PER SECTION1000.000 PICOFARADS SINGLE SECTION
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS+0.0 TO 70.0 SINGLE SECTION
TERMINAL LENGTH1.000 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-2.000 TO 2.000 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial