5996-00-144-1759 AMPLIFIER,INTERMEDIATE FREQUENCY Index 5985-00-144-1762 ATTENUATOR,FIXED

National Stock Number:
5910-00-144-1760

Federal Supply Class:
5910

National Item Identification Number:
001441760

Description:
CAPACITOR,FIXED,PAPER DIELECTRIC

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having paper as the dielectric material. It may be a single unit or consist of two or more fixed units which cannot be seperated. For items whose dielectric material consist of plasticized (plastic impregnated) paper or paper-plastic combinations, see CAPACITOR, FIXED, PLASTIC DIELECTRIC. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
103P54101884EXXELIA USA, INC.
103P54156289SPRAGUE ELECTRIC CO WORLD HQS
7902712-0890536LOCKHEED MARTIN CORP
NFTH1P68S93790CORNELL-DUBILIER ELECTRONICS, INC.


Techincal Specification:
BODY DIAMETER0.562 INCHES NOMINAL
BODY LENGTH1.880 INCHES NOMINAL
BODY STYLEW/THD BUSHING MTG, TERMINALS ON OPPOSITE ENDS
CAPACITANCE VALUE PER SECTION0.680 MICROFARADS SINGLE SECTION
CASE MATERIALMETAL
CONTINUOUS CURRENT RATING IN AMPS5.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT REFERENCE TEMP30000.0 MEGOHMS
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.312 INCHES
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORFEEDTHROUGH
TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT90536-7902712 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial