5935-00-138-7491 CONNECTOR,RECEPTACLE,ELECTRICAL Index 6625-00-138-7493 OSCILLOSCOPE

National Stock Number:
5910-00-138-7492

Federal Supply Class:
5910

National Item Identification Number:
001387492

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
M39006-09-427081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC39006-981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY DIAMETER0.312 INCHES MAXIMUM
BODY LENGTH0.719 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITIVE ELECTRODE MATERIALTANTALUM
CAPACITANCE VALUE PER SECTION120.000 MICROFARADS SINGLE SECTION
CASE INSULATION MATERIALPLASTIC
CASE MATERIALMETAL
DC LEAKAGE AT MAXIMUM OPERATING TEMP7.0 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP1.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT36.8000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS50.0
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORAN-3 AND C
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION15.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL LENGTH2.250 INCHES NOMINAL
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MILC39006/9 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION