BODY HEIGHT | 0.370 INCHES MAXIMUM |
BODY LENGTH | 0.710 INCHES MAXIMUM |
BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
BODY WIDTH | 0.590 INCHES MAXIMUM |
CAPACITANCE VALUE PER SECTION | 180.000 PICOFARADS SINGLE SECTION |
CASE MATERIAL | PLASTIC |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.313 INCHES MINIMUM AND 0.375 INCHES MAXIMUM |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.0750 |
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 15000.0 MEGOHMS |
INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
NONDERATED OPERATING TEMP | -55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS | -20.0 TO 100.0 SINGLE SECTION |
TERMINAL LENGTH | 1.250 INCHES MINIMUM |
TERMINAL SURFACE TREATMENT | SOLDER |
TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
TEST DATA DOCUMENT | 01714-GA10816 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
TOLERANCE RANGE PER SECTION | -0.50 TO 0.50 PERCENT SINGLE SECTION |