Description:
CAPACITOR,FIXED,MICA DIELECTRIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CM30ED272GP381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC5-481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.800 INCHES NOMINAL
BODY LENGTH0.800 INCHES NOMINAL
BODY WIDTH0.250 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
CAPACITANCE VALUE PER SECTION2700.000 PICOFARADS SINGLE SECTION
CASE MATERIALPLASTIC
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0015
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP7.5 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 150.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS-20.0 TO 100.0 SINGLE SECTION
TERMINAL LENGTH1.120 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-5+4 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-2.00 TO 2.00 PERCENT SINGLE SECTION