Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
1872821-4455972HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS
21351-693958REPUBLIC ELECTRONICS CORP S INC
267732-4449956RAYTHEON COMPANY
579R589H0697942NORTHROP GRUMMAN SYSTEMS CORPORATION
7119072-36706481NORTHROP GRUMMAN SYSTEMS CORPORATION
8137-902W5R0-334K72982ERIE SPECIALTY PRODUCTS INC
A200-433651504RAVEN ELECTRONICS CORP
C11A1-334J59942AVX FILTERS CORPORATION
C11A1-334M16546MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
C11C334J16546MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
C11C334K16546MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
C11C334M16546MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
CAC05Z5U334M050A14674CORNING GLASS WORKS
CN07M334K-D-R50056PIEZOTHERMX CORPORATION
EL50AD334J20932ILLINOIS TOOL WORKS INC EMCON DIV
R-1277-60TCV9ARIZONA CAPACITORS, INC
SSM-.33-101909052SAFT AMERICA INC.
X90C334J59942AVX FILTERS CORPORATION


Techincal Specification:
BODY HEIGHT0.185 INCHES MAXIMUM
BODY LENGTH0.450 INCHES MAXIMUM
BODY WIDTH0.140 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
CAPACITANCE VALUE PER SECTION0.330 MICROFARADS SINGLE SECTION
CASE MATERIALPLASTIC
CONTINUOUS CURRENT RATING IN AMPS0.05
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.0000
INSULATION RESISTANCE AT REFERENCE TEMP10000.0 MEGOHM-MICROFARADS
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-1
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-15.0 TO 15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION