CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CL17BS151MPG81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC3965-1981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY DIAMETER1.125 INCHES NOMINAL
BODY LENGTH2.812 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINAL(S) ON ONE END
CAPACITIVE ELECTRODE MATERIALTANTALUM
CAPACITANCE VALUE PER SECTION150.000 MICROFARADS SINGLE SECTION
CASE MATERIALMETAL
DC LEAKAGE AT MAXIMUM OPERATING TEMP235.0 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP28.000 MICROAMPERES
FEATURES PROVIDEDHERMETICALLY SEALED CASE
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS75.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION270.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
POWER FACTOR AT REFERENCE TEMP IN PERCENT45.0000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL LENGTH0.312 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY1 SOLDER STUD AND 1 TAB, SOLDER LUG
TEST DATA DOCUMENT81349-MIL-C-3965/19 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION